556 Drs. R B. Denison and B. D. Steel .
[ Oct. 14 , larger deflection was obtained when " B " was made negative than when it was made positive .
These results correspond with the known fact that negative ions have a greater velocity than positive ions .
As was to be expected , having regard to the unstable nature of the arc , the galvanometer deflections were not very steady .
They were , however , invariably in the directions indicated , according as the polarity of the electrodes was transposed , and endured as long as the arc covered the aperture in the upper electrode .
The writer is indebted to Mr. J. C. M. Stanton and Mr. R.C. Pierce for their skilful assistance in carrying out the above experiments .
The Accurate Measurement of Ionic Velocities .
By R. B. Denison , M.Sc .
, Ph. D. , and B. D. Steele , D.Sc .
( Communicated by Sir William Ramsay , K.C.B. , F.R.S. Received October 14 , \#151 ; Read November 16 , 1905 .
) ( Abstract .
) The value of the direct method of measuring ionic velocities has been seriously diminished in the past by the necessity of using gelatine solutions in the measuring apparatus , and by the restriction of the method to more concentrated solutions .
The authors have succeeded in devising an apparatus in which it is possible to compare and measure the velocities of the ions of a given salt without using gelatine or other partitions during the actual experiment ; and they have also succeeded in extending the method to the measurement of dilute solutions .
The apparatus consists of two reservoirs , each supplied with a special electrode vessel , and of a measuring-tube of known cross-section , in which the solution to be measured is placed .
One of the reservoirs contains a solution of a salt which has a slower cation than that to be measured , and the other a solution of a salt with a slower anion than that to be measured .
When a current is passed in the proper direction through such a system , an electrolytic margin of constant velocity is formed , provided certain conditions are fulfilled .
These conditions have been already described.* The measuring tube is provided at each end with a parchment-paper partition , which facilitates the formation of a sharp electrolytic margin between the indicator * Masson , ' Phil. Trans. , ' A , 1899 , p. 331 ; Steele , A , 1902 , p. 105 .
1905 .
] The Accurate Measurement of Ionic Velocities .
' 55 7 and measured solutions , and these partitions are so arranged that they can be removed from the ends of the measuring-tube after the margins have been formed .
There is thus no membrane of any sort between the two electrodes , and electrolysis is not complicated by the occurrence of electric endosmose .
The formation of bubbles of hydrogen or oxygen gas in the electrode vessels is prevented by the use of unpolarisable electrodes .
The transport number and the average absolute velocity of the ions of a number of salts have been measured with very satisfactory results .
Transport numbers have been measured at dilutions down to one-fiftieth normal , and the following results will serve to illustrate the degree of accuracy obtained .
Transport number .
__ A r~ -------^ Denison and By Hittorf 's Salt .
Concentration .
Steel .
method .
KCl ... ... ... ... ... nj 10 0-508 0-508 n/ 50 0-507 0-507 NaCl ... ... ... ... .
n/ 10 0-618 0-617 to/ 50 0-614 0-613 HC1 ... ... ... ... ... to/ 10 0165 0172 KOH ... ... ... ... . .
nj1 0-738 0735 The values which we have obtained for the average absolute velocities confirm in a remarkable manner those calculated from conductivity data by Kohlrausch .
This will be seen from the following examples:\#151 ; T = 18 ' C. Velocities in cm./ sec. Salt and Anion velocities .
Cation velocities .
concentration .
Found .
Calculated .
Found .
Calculated .
Denison and Steel .
Kohlrausch .
Denison and Steel .
Kohlrausch .
KCl 0-l\#187 ; ... 0 -000582 0-000588 0 -000563 0 *000568 1STaCl 0 T n ... 0 -000591 0 -000591 0 -000367 0 *000367 KC103 0 *1 n ... 0 -000474 0-000476 O -000549 0 *000550 HC1 0 *1 n ... 0-000600 0 -000626 0 -00303 0 *00303 It is claimed for the present method that it is at least as accurate as that of Hittorf , and an experiment can be carried out in about one-tenth of the time .
It also gives a means of comparing the degree of dissociation of salts containing a common ion .
2 q 2