On the Automatic Registration of Magnetometers , and Meteorological Instruments , / by Photography.-No .
IV .
By CHARLES BROOKE , M.B. , F.R.S. Received May 8 , -Read June 19 , 1851 .
On the Automatic Temperature Compensation of the Force Magnetometers .
A PORTION of the funds liberally contributed by the Government for the advancement of science , and placed at the disposal of the President and Council of the Royal Society , having been entrusted to the author for the accomplishment of the above object on a plan which was submitted to the Astronomer Royal and Colonel SABINE in the spring of last year* , and by them considered feasible , he considers that he cannot better fulfil the obligation of reporting progress at the present period , than by laying before the Royal Society a description of the instruments now constructed .
So long as the results of the variations of magnetic force were deduced from eyeobservation only , at the periods of which the temperature as well as the position of the magnets was recorded , a correction for the influence of change of temperature on the instruments themselves could be readily estimated and applied ; but in deducing mean values from the photographic registers , especially those for intervals involving considerable changes of temperature , it is manifest that the greatest degree of accuracy cannot be attained , unless either the apparent values were individually corrected by means of a separate register of the thermometer enclosed in the box with the magnet , or the instrument possessed within itself an approximate automatic correction for the effects of change of temperature .
The object would not be unattainable by the former means , but the process would be both difficult and laborious ; it therefore appeared more desirable to attempt its accomplishment by the latter .
Referring therefore to the equation of equilibrium of the bifilar magnet , viz. mX=W l sin If in which m is the magnetic moment of the bar , X the horizontal component of the earth 's magnetic force , W the weight of the suspended bar and its appurtenances , I the length of the suspension skeins , a and b the upper and lower intervals of their centres , and d the angle of torsion , it is evident that the object in view would be accomplished , if by any mechanical agency either of the quantities W , a , or b could be simultaneously influenced by change of temperature , and proportionally to the altered value of m. As it would be desirable that the correction should involve the small coefficient of the second power of the temperature , a very definite value of which has been determined* , it was at first proposed to act on W by means of a hollow glass globe attached to the suspension frame of the magnet , with a vertical tubular stem dipping into a cup of mercury .
It is clear that as the elastic force of the air contained in the bulb is diminished by heat , a column of mercury in the stern would fall , and the diminution of the suspended weight thus occasioned , might by a due ( Idjustment of the capacity of the bulb be rendered equivalent to the constant part of the loss of power in the bar , and would thus represent the coefficient of the first power of the temperature , while an equivalent to the coefficient of the second power might be obtained by a due adjustment of the diameter of the stem .
It is evident that the smaller the diameter of the stem , or in other words , the longer the space occupied by the mercury depressed during a large interval of temperature , the greater would be the difference of the spaces corresponding to successive small intervals .
But this arrangement would be liable to several small sources of error ; first , an alteration of the suspended weight by hygrometric changes in the length of the suspension skein ; secondly , a change in the bulk of the air in the bulb corresponding to barometric changes ; and thirdly , a small and uncertain secular variation , from the evaporation of mercury in the cistern in which the stein would be immersed .
From these considerations , it has been deemed advisable to abandon the attempt to introduce in the compensation an equivalent for the small coefficient of t2 , and to rest satisfied with acting on a or b by means which would effect an equal change for equal intervals of temperature , and would therefore represent the coefficient of t only .
Metallic expansion naturally suggested itself as the means of accomplishing this object , and b the lower interval of the skeins as the most appropriate point of application , inasmuch as the compensating apparatus would then be in close proximity with the magnet , and being isolated from the surrounding atmosphere by enclosure in the same case or cases , might be presumed to vary in temperature slowly and simultaneously with the magnet ; and if the changes in temperature were not sufficiently simultaneous , the radiating capacity of the magnet might be increased by partially coating it with dead-black varnish , or diminished by gilding and burnishing it , to any required extent .
The compensating apparatus consists of a glass rod clamped at its middle point to the centre of magnet , the axes of the rod and bar being parallel : the free ends of the rod are enclosed in two zinc tubes , at the inner ends of which , where they nearly meet in the centre , and to their upper surface , two hooks are attached : two loops at the ends of the suspension skein are attached to these hooks , the skein passing over a pulley at the point of suspension .
Towards either end , the rod and tubes are connected by a moveable clamp , by which the two may be clamped together at any required distance from the centre .
It is evident that by elevation of temperature the free ends of the zinc tubes will be approximated to each other by a quantity equal to the difference of the expansion of the lengths of zinc and glass that intervene between the sliding clamps and the free ends of the tubes , and consequently that a diminution to the same extent of the distance between the lower ends of the suspension skein will take place .
The variation of the interval between the lower ends of the skein , corresponding with any given variation of temperature , may be made to bear any required ratio to the whole interval , first by a due adjustment of the upper and lower intervals of the skein , and secondly by varying the position of the sliding clamps , that is , of the acting lengths of the expanding tubes : the former may be considered as a coarse , the latter as a fine adjustment .
The glass rod rests on rollers attached to the under surface of the tubes opposite to the hooks , in order that no jerking may be occasioned by the expansion or contraction of the zinc tubes .
By these means the quantity b in the preceding formula may be made to vary by change of temperature , proportionably to the change of the quantity m with any required degree of exactness ; so far , at least , as the variation of m is directly proportional to the variation of ; temperature .
In the adjustment of the instrument the following steps are necessary .
First , let the temperature coefficient of the bar be determined by the method described in the Paper No. III .
previously mentioned ; secondly , let the lower interval of the skeins be taken , such that the ratio of the difference of linear expansion of the whole length of the tubes and glass rod ( which for convenience is made the same length as the bat ) , between 320 F. and any given higher temperature , say 920 F. , to the distance between the threads , may be considerably less than the whole correction for that interval of temperature ; ample scope will thus be allowed for determining by experiment the requisite amount of compensation , as is the case in the adjustment of chronometers .
The pulley over which the skein passes at the upper point of suspension being made of brass , there will be an increase of the upper interval between the threads , with increase of temperature : in order to compensate for this , it will be necessary to take the acting lengths of the compensator somewhat greater than the calculated length , expressing the value of the temperature coefficient .
The instrument having been thus approximately adljusted , the magnet and its appurtenances are now to be enclosed in a rectangular jacketed zinc box .
The water in the jacket may be raised to any required temperature , and the temperature maintained nearly constant for any required period , by heating a pipe connecting the inlet and outlet of the jacket by a jet or jets of gas .
A uniformity of the temperature of the jacket is obtained by the introduction of suitable diaphragms to ensur ea complete circulation throughout its entire extent .
A photographic register of the variations of the instrument is now to be obtained by the means described in the two first papers of this series* , the temperature of a thermometer enclosed in the zinc box , and placed as near as possible to the magnet being simultaneously recorded at convenient intervals of time , corresponding to temperature changes of not more than two degrees .
If the change of temperature is slow , that is , if a variation of 40 ?
FAHR. is spread over a space of at least six or eight hours , the temperature of the mercury may fairly be assumed to be the same as that of the bar .
If , in order to avoid the consumption of time , or for any other reason , it should No found desirable to observe during more rapid changes of temperature , some such means as those before mentioned must be employed to ensure a uniformity of radiating capacity in the magnet , the compensator , and the thermometer .
A photographic register of the bifilar variations during known changes of temperature having been thus obtained , should now be compared with that of another bifilar instrument of which the temperature has undergone comparatively little variation , as will be the case under ordinary circumstances : a comparison of these will readily show whether the instrument under trial is overor under-compensated , and the requisite correction may be made by shifting the sliding clamps .
A few repetitions of the same process will suffice to give the requisite accuracy of correction .
It may be remarked that the most satisfactory method would be to register simultaneously a carefully compensated instrument on the same sheet of paper ; the means of doing this are not however at present in existence .
Compensation of the Balanced Magnetometer .
The horizontal displacement of the centre of gravity by metallic expansion is the most palpable means of effecting a compensation for the changes of temperature in this instrument ; the only question is the precise method by which the numerical value of the temperature coefficients can be most nearly represented .
The plan adopted has been that of attaching a small thermometer parallel to the axis of the magnet , and as nearly as possible in the same horizontal plane with the centre of gravity of the magnet and its appendages .
The statical moment of the mercury displaced from the bull ) of the thermometer by any given elevation of temperature , as xabove 32 ?
FAHR. , may be represented by the same formula which expresses the temperature coefficients , namely , cx + ex2 .
For let w be the weight of mercury contained in one degree of the tube , and let the tube be taken such that the distance front the centre of the bulb ( which is presumed to be a symmetrical figure of revolution ) to the point 320 FAHR. may be kc , and length of one degree 2ke ; then at any temperature 320+x0 the statical moment of the mercury displaced by a small change of temperature , dx , will be w ( kc+2kex ) dv , INSTItUM ENTS , BY PHOTOGRAPHY .
23 and consequently the statical moment of the mercury displaced between the temperatures of 32 ?
and 320+x0 will be ( kcx+kex2 ) w ; let now v be the weight which , placed at a unit of distance from the point of support , will represent the temperature correction for 10 above 32 ?
FAHR. ; it will only remain to obtain a bulb of such size that kw _v ; we shall then clearly have the statical moment of the mercury displaced from the bulb by x0 of elevation of temperature above 32 ' FAHR. , and transferred to the vacant portion of the tube represented by ( cx+ex2 ) v , and consequently a correction in weight equivalent to the temperature coefficient will have been applied to the bar .
As the change of density of the thread of mercury in the stem has not been taken into the account , it will be better to place the point of the tube which corresponds to a distance kc below the point 320 opposite the knife-edge ; the error from this cause will then be quite negligible .
The value of v is to be determined experimentally by observing the displacement of the register line occasioned by a small known weight placed on the bar at a known distance from the point of support , and comparing this with the scale coefficient obtained in the usual manner .
Owing to the short period of time that has elapsed since the completion of the instruments , and the difficulty of making accurate magnetic observations in a locality subject to the constant tremors and vibrations of a London thoroughfare , the constants have not been determined with a sufficient degree of accuracy for publication ; when satisfactorily determined , they will be communicated to the Society in the form of a Supplement to this paper .
Figs. I and 2 .
Plan and elevation of the bifilar compensator , half the actual size .
aa the magnet , b the clamp which attaches the glass rod to the magnet .
cc the zinc tubes enclosing the glass rod .
dd the adjusting clamps , consisting of two parts ; the outer encircles the zinc tube , the inner passes , and nearly fills the interval , between the tube and glass rod .
They are capable of sliding for adjustment when the screws are loosened ; when tightened , the rod and tubes are held together .
ee screws for adjusting the distance between the hooks h It ; these should be withdrawn , when the clamps d are fixed .
o o , fig. 2 , are the ends of the clamping pieces interposed between the tubes and the rod .
Fig. 3 .
The brass collar to which the hook is attached seen in section , full size .
The glass rodf rests on a roler g , that there may be no jerking in the expansion and contraction of the tube ; ii two screws for fixing the collar while the scale and temperature coefficients are determined ; when these are tightened the clamps d and screws e should be relaxed .
Fig. 4 .
Plan of the balanced magnet compensator .
kk the magnet .
lI the thermometer tube held in two Is by a spring m tightened by a screw .
nn the clamp that attaches the magnet to the frame in which the agate knifeedges are fixed .
.thJi..7hz/ hg..NfDCCCLT[ . ?
lafriE.yz ?
4 .
'V j It It ci 6r c C ... .---. .
I ------C eS ---__ a -9 a r. z. 0 0.tIp c0 __ CpC _____ ________ -C ?
ci LA ( A -_________________________ 14y 3.Ft z 1y .
4.c_ _____ __ L S